151. You can also store environment variable files in Quality Center.
A) True
B) False
Ans: A
151. ....... built-in environment variable that tells version of the OS on which you are working.
A) OS
B) OS_Ver
C) OSVER
D) OSVersion
Ans: D
153. Random number parameters are appropriate for non-numeric
values, such as text or hypertext links.
A) True
B) False
Ans: B
154. Regular expressions enable QuickTest to identify objects and text strings with undependable values.
A) True
B) False
Ans: A
156. You can use regular expressions only for values of type string and number.
A) True
B) False
Ans: B
157. If you expect the value of a property to change in an unpredictable way during each run session, you can use regular
expressions
A) True
B) False
Ans: B
158. All ........ are automatically treated as regular expressions.
A) programmatic description
B) Window
C) WinObject
D) Collection
Ans: A
159. If a backslash character is used before a character that has no special meaning, the backslash is ignored.
A) True
B) False
Ans: A
160. You can use regular expressions in the Find what and Replace with strings to enhance your search.
A) True
B) False
Ans: A
161. Regular Expressions can also be used with XML checkpoints.
A) True
B) False
Ans: A
162. What is the Regular Expression Matching Zero or More Specific Characters
A) x
B) #
C) *
D) &
Ans: C
163. Virtual objects enable you to record and run tests on objects that are normally recognized by QuickTest.
A) True
B) False
Ans: B
164. In the test results, the virtual object is displayed as though it is a standard class object.
A) True
B) False
Ans: A
165. QuickTest does not support virtual objects for ....... recording.
A) analog
B) low-level
C) normal
D) both A & B
E) both A & C
Ans: D
166. You can use the Object Spy to view virtual object properties.
A) True
B) False
Ans: B
167. You cannot insert any type of checkpoint on a virtual object
A) True
B) False
Ans: A
168. The ............ contains all the virtual object collections defined on your computer.
A) Virtual Objects Manager
B) Virtual Manager
C) Virtual Object Manager
D) Virtual Object Wizard
Ans: C
169. Extention of virtual object collection files
A) .vcf
B) .vot
C) .vct
D) .vcd
Ans: B
170. You can remove virtual objects from your test by ....... these objects.
A) disabling recognition of
B) deleting
C) deleting virtual object collection files of
D) All of Above
E) both A & B
Ans: E
171. When you want QuickTest to recognize virtual objects during recording, ensure that the ....... check box in the
General tab of the Options dialog box is cleared.
A) Disable recognition of virtual object Files while recording
B) Disable recognition of virtual object Collection while recording
C) Disable recognition of virtual objects while recording
D) Enable recognition of virtual objects while recording
Ans: C
172. QuickTest identifies a virtual object according to its ......
A) Properties
B) boundaries
C) Object Spy
D) Edges
Ans: B
173. Recovery scenarios activate specific recovery operations when ......... occur.
A) Specific Errors
B) Test Errors
C) Trigger Events
D) QTP Errors
Ans: C
174. You can also control and activate your recovery scenarios during the run session by inserting .............. into
your test.
A) Trigger Events
B) Recovery Events
C) Recovery Statements
D) Catch Statements
Ans: C
175. If you choose On error in the Activate recovery scenarios box in the Recovery tab of the Test Settings dialog box,
the recovery mechanism does not handle triggers that occur in the last step of a test.
A) True
B) False
Ans: A
176. By default, recovery scenario operations are activated only after a step returns an error.
A) True
B) False
Ans: A
177. A ....... is a convenient way to organize and store multiple recovery scenarios together.
A) recovery file
B) recovery folder
C) Recovery Log
D) Log File
Ans: A
178. The Recovery Scenario Manager dialog box enables you to create and edit recovery files, and does not let you create
and manage the recovery scenarios stored in those files.
A) True
B) False
Ans: B
179. Each recovery scenario is represented by an icon that indicates its type.
A) True
B) False
Ans: A
180. The Recovery Operations screen in Recovery Scenario Wizard enables you to manage the collection of ........ in the
recovery scenario.
A) recovery operations
B) recovery Files
C) Trigger events
D) All of Above
Ans: A
181. If you define a Restart Microsoft Windows recovery operation, it is always inserted as the last recovery operation,
and you can change its position in the list.
A) True
B) False
Ans: B
182. If more than one scenario uses a function with the same name from different function libraries, the recovery process
may fail.
A) True
B) False
Ans: A
183. To debug a function library, you must first associate it with a test and then debug it from that test.
A) True
B) False
Ans: A
184. To detect and isolate defects in a test or function library, you can control the run session using the .... command
A) Pause
B) Run
C) F14
D) Session
Ans: A
185. When the test or function library run stops at a breakpoint, you can use the ...... to check and modify the values of
VBScript objects and variables.
A) Debug Window
B) Debug Dialog
C) Debug Viewer
D) Debug page
Ans: C
186. While the test and function libraries are running in debug mode, they are read-only
A) True
B) False
Ans: A
187. You cannot debug a file that is called using an ...... statement, or any of the functions contained in the file.
A) ExecuteFiles
B) Execute_File
C) Execute-File
D) ExecuteFile
Ans: D
188. The debug session can continue at the backend while you can perform file operations like opening a new test etc.
A) True
B) False
Ans: B
189. Any changes you apply to external resources saved in the file system, such as function libraries, are implemented
only when the test is closed and reopened but any changes you apply to any external resource that is saved in your Quality
Center project, such as a function library, will be implemented immediately.
A) True
B) False
Ans: B
190. You can use the .......... command to begin your debug session at a specific point in your test.
A) Start from Step
B) Run to Step
C) Run from Step
D) Start to Step
Ans: A
191. You can specify the time (in milliseconds) QuickTest pauses between each step by modifying the ..... option in the
Run tab of the Options dialog box (Tools > Options).
A) Delay step execution by
B) Delay every step execution by
C) Delay all steps execution by
D) Delay each step execution by
Ans: D
192. To display the Debug toolbar, choose ............
A) View > Toolbar > Debug
B) View > Toolbars > Debugs
C) Views > Toolbar > Debug
D) View > Toolbars > Debug
Ans: D
193. You can install the QuickTest...... add-ins (Web, ActiveX, Visual Basic) when you install QuickTest Professional, or
you can install the QuickTest built-in add-ins at a later time by running the installation again.
A) internal
B) external
C) built-in
D) All of above
Ans: C
194. Add-ins that are installed separately from the QuickTest Professional installation are referred to as .......
add-ins.
A) internal
B) external
C) built-in
D) built-out
Ans: B
195. When QuickTest opens, you can choose which of the installed add-ins you want to load using the QuickTest Professional
- ...... dialog box.
A) Add-In Window
B) Add-In
C) Add-In Manager
D) Add-In Management
Ans: C
196. Installing and Loading an Add-in is one and the same thing.
A) True
B) False
Ans: B
197. You can install Add-in Upgrade patches by running the relevant patch executable from the \...... folder.
A) AddinsUpdate
B) AddinsUpgrade
C) Addins_upgrade
D) Both A & B
Ans: B
198 In Add-in Manager dialog box, Time-Limited column displays values only when using a QuickTest seat license — not a
concurrent license.
A) True
B) False
Ans: A
199. You can view the list of add-ins that are currently installed or loaded by choosing ...................
A) File > Settings
B) Tools > Options and click the General tab.
C) Help > About QuickTest Professional.
D) both A & B
Ans: C
200. To maximize performance and object identification reliability, load all the add-ins.
A) True
B) False
Ans: B